Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38461472

RESUMO

We evaluated the diagnostic performance of a deep-learning model (DLM) (CorEx®, Spimed-AI, Paris, France) designed to automatically detect > 50% coronary stenosis on coronary computed tomography angiography (CCTA) images. We studied inter-observer variability as an additional aim. CCTA images obtained before transcatheter aortic valve implantation (TAVI) were assessed by two radiologists and the DLM, and the results were compared to those of invasive coronary angiography (ICA) used as the reference standard. 165 consecutive patients underwent both CCTA and ICA as part of their TAVI work-up. We excluded the 42 (25.5%) patients with a history of stenting or bypass grafting and the 23 (13.9%) patients with low-quality images. We retrospectively subjected the CCTA images from the remaining 100 patients to evaluation by the DLM and compared the DLM and ICA results. All 25 patients with > 50% stenosis by ICA also had > 50% stenosis by DLM evaluation of CCTA: thus, the DLM had 100% sensitivity and 100% negative predictive value. False-positive DLM results were common, yielding a positive predictive value of only 39% (95% CI, 27-51%). Two radiologists with 3 and 25 years' experience, respectively, performed similarly to the DLM in evaluating the CCTA images; thus, accuracy did not differ significantly between each reader and the DLM (p = 0.625 and p = 0.375, respectively). The DLM had 100% negative predictive value for > 50% stenosis and performed similarly to experienced radiologists. This tool may hold promise for identifying the up to one-third of patients who do not require ICA before TAVI.

2.
Ann Cardiol Angeiol (Paris) ; 72(5): 101641, 2023 Nov.
Artigo em Francês | MEDLINE | ID: mdl-37703710

RESUMO

Chest pain is one of the major causes for admission in the Emergency Room in most countries and one of the principal reasons for urgent consultation with a cardiologist or a general practitioner. After clinical examination and initial biological measurements, substantial patients require further explorations. CT scan allows the search for pulmonary embolism in the early stage of pulmonary arteries iodine contrast exploration. During the same exam at the systemic arterial phase, the search for aortic dissection or coronary artery disease is possible while exploring the later contrast in the aortic artery. This triple rule-out exam allows correct diagnosis in case of acute chest pain with suspected pulmonary embolism, aortic dissection and other acute aortic syndromes or acute coronary syndrome. But X-rays are substantially increased as well as iodine contrast agent quantity while exam quality is globally decreased. Artificial intelligence may play an important role in the development of this protocol.

4.
Int J Cardiovasc Imaging ; 36(8): 1551-1557, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32306158

RESUMO

A fluoroscopic view perpendicular to the aortic valve annulus is required during transcatheter aortic valve implantation (TAVI) for obtaining an optimal deployment of the bioprosthesis. By predicting c-arm angulation, pre-procedural MDCT could decrease the number of aortograms, shorten the time of the procedure and reduce the amount of intra-arterial contrast agent. The aim of our study was to assess the accuracy of MDCT in predicting c-arm angulation at the cath. lab. In this single center study, we investigated MDCT prediction of c-arm angulation in patients having undergone a TAVI procedure using SAPIEN 3® (Edwards Lifesciences, USA). Prior to the procedure, an experienced radiologist had reported the angulation using dedicated software (CTreport). After the procedure, a blinded experienced radiologist retrospectively measured the angles using the same method (CTstudy). Interobserver variability was drawn from the comparison between CTreport and CTstudy. Then, the mean angular difference between the predicted MDCT angles (CTstudy) was compared to the working view recorded at the cath. lab. Seventy-nine patients (M/F = 0.65; mean age: 85.2 years ± 5.3) were included. Interobserver variability was 5.9 ± 6.1°. The mean absolute difference between MDCT and fluoroscopy was 8.8 ± 7.1°. The present study showed that MDCT could predict the coplanar fluoroscopic angles prior to TAVI using a balloon-expandable bioprosthesis Sapien 3® placed via a transfemoral approach with a mean angular difference of 8.8 ± 7.1°. Reproducibility was considered good as the mean difference between two independent measures was 5.9 ± 6.1°.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Bioprótese , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...